HOME TRANSFORMER COOLING FANS CONFINED SPACE BLOWER VAULT BLOWERS QUALITY DOWNLOAD INFORMATION CONTACT BUY NOW

8" Portable Blower

CONFINED SPACE BLOWERModel: PBF08A115A (115 Volts A.C.)
Download Data Sheet
Model: PBF08A012D (12 Volts D.C.)
Model: PBF08A000C (115 Volts A.C./D.C.)

Lightweight high performance vane axial fan. The Series 8 fan is used to exhaust or supply large volumes of air in confined spaces. Equipped with 10 feet of SO cord with a NEMA dead front plug.

The spun aluminum housing is heat treated and is reinforced by a cast aluminum vane element for air flow straightening. Assembly is powder coated for a durable, attractive appearance.

Composite propeller with die-cast aluminum hub locks tough, resilient polypropylene blades. Blades have a true airfoil design for high efficiency and low noise.

Zinc plated steel wire guard meets OSHA safety requirements.

AIR FLOW CERTIFIED TO AMCA STANDARD 210-67 and ATT&T E.L. 2723/P.L. 2709
Air Delivery
Model
CFM (8" dia. flexible duct)
Free Air
(No Bends)
15' Duct
& One 90° Bend
15' Duct
& Two 90° Bends
PBF08A115A

PBF08A000C

PBF08A012D

731

842

793

488

527

514

428

488

473

Specifications
Model
HP
Voltage
Amps
RPM
Motor Type
Approximate
Brush Life
Shipping
Weight

PBF08A115A

PBF08A000C

PBF08A012D

1/8

1/8

1/8

115 VAC

115 V AC/DC

12 V DC

1.26

2.1

13

3450

3300

3300

PSC

Series Wound

Shunt Wound

Brushless

1000 hrs

700 hrs

23 lbs.

21 lbs.

20 lbs.


CONFINED SPACE BLOWER

Model: PCF08A115A (115 Volts A.C.)
Download Data Sheet
Model: PCF08A012D (12 Volts D.C.)
Lightweight high performance tube axial fan. The PCF08 fan is used to exhaust or supply large volumes of air in confined spaces. Equipped with 10 feet of SO cord with a NEMA dead front plug, or two pliers type battery clamps.

The steel housing is fully welded for strength and durability. The entire assembly is powder coated for a durable, attractive appearance. Comfortable molded handle with shielded on-off switch.

Die-cast aluminum propeller. Blade is powder coated for durability.

Bright plated steel wire guard on both inlet and exhaust meets OSHA safety requirements (no openings greater than 1/2 inch).

Blowers provide 750 CFM free air delivery.

Specifications
Model
HP
Voltage
Amps
RPM
Motor Type
Approximate
Brush Life
Shipping
Weight

PCF08A115A

PCF08A012D

1/6

1/8

115 VAC

12 V DC

1.7

12.3

3300

3300

PSC

Shunt Wound

Brushless

700 hrs

20 lbs.

20 lbs.


CONFINED SPACE BLOWERModel: PCC08A115E (115 Volts A.C. 15' attached duct) Download Data Sheet
Model: PCC08A115F (115 Volts A.C. 25' attached duct)
Model: PCC08A012E (12 Volts D.C. 15' attached duct)
Download Data Sheet
Model: PCC08A012F (12 Volts D.C. 25' attached duct)

Lightweight high performance tube axial fan. The PCC08 fan is used to exhaust or supply large volumes of air in confined spaces. Equipped with 10 feet of SO cord with a NEMA dead front plug, or two pliers type battery clamps.

Extended housing carries 15 or 25 feet of 8" diameter flexible ducting. Ducting is permanently attached, the steel carrier protects the ducting from abrasion, soiling and sunlight. The steel housing is fully welded for strength and durability. The entire assembly is powder coated for a durable, attractive appearance. Comfortable molded handle with shielded on-off switch.

Die-cast aluminum propeller. Blade is powder coated for durability.

Bright plated steel wire guard on both inlet and exhaust meets OSHA safety requirements (no openings greater than 1/2 inch).

Blowers provide 750 CFM free air delivery

Specifications
Model
Attached
Duct
HP
Voltage
Amps
RPM
Motor Type
Approximate
Brush Life
Shipping
Weight

PCC08A115E
PCC08A115F

PCC08A012E
PCC08A012F

15 feet
25 feet

15 feet
25 feet

1/6

1/8

115 VAC

12 V DC

1.7

12.3

3300

3300

PSC

Shunt Wound

Brushless

700 hrs

38 lbs.

38 lbs.

* Test Method: AMCA 210-99, fig. 12/ ISO 5801, fig. 71b, fan installation type A, free inlet and free outlet. Other impeller arrangements will affect the performance.
** Sound levels listed here were determined under laboratory conditions. Many factors can influence fan sound levels that are beyond the control of the propeller manufacturer or California Turbo, Inc; including inlet geometry and obstructions in the airflow. Please use this information for comparison purposes only.
NOTE: Electrical and noise data are supplied by the motor and propeller manufacturers, respectively. These values have not been independently verified by California Turbo, Inc.
California Turbo, Inc. reserves the right to make product changes from time to time, without prior notification.

10721 Business Drive, Fontana, CA 92337 USA
Phone: 909-854-2800 or 800-448-1446
Fax: 909-854-2801
E-mail: websales@californiaturbo.com
Welcome to California Turbo and thank you for visiting our website.